News:

New Wiki available at http://wiki.gstwins.com -Check it out or contribute today!

Main Menu

No spark, DESESPERATE

Started by chuskeyto, July 20, 2015, 04:15:14 PM

Previous topic - Next topic

chuskeyto

Hello! First of all introduce myself, my name's Jesús Im from Spain I come from the spanish brother forum http://www.clubgs500.com/ so excuse if my english is bad. I have a problem that brings me get crazy from 5 days ago. I dont have spark at the coils after having changed the engine, and I dont know why. I tried all but I cant fix the problem!!

My suzuki gs is from 2003, but this is the third engine that I put into my suzuki. The first engine was the grey engine. In my second change I put and old black motor from a 1994 bike, but keeping the stator cover of the alternator and the pick up of the first engine. Now with the third engine I kept the stator cover of the alternator and the pick up too. (as a curious comment that the second engine didnt have neutral selector wire and the ignition works fine, something imposible according to the wiring diagram attached to the end, but I gave no importance because everything worked fine) So all the electrical parts are the electrical parts that all time have been working well (I have changed this third engine because I seized up it, not for a electrical problem). I have checked this:

1º Resistance measurement pulse generator (376 ohms according manual, OK)
2º Resistance measurement between pulse generator (Br) and ground (infinite ohms, according manual, OK)
3º Measurement of resistance in primary winding coil high (5,4ohms and 5,3ohms according manual, OK)
4º Measurement of resistance between input terminals and plug cap, (secondary winding coil high) (29,5kohms and 30,1kohms in the manual lays between 18 and 30 kohms but I think that this is not the problem, because the measurements are nearly to the limit, and its difficult that the 2 coils fail at the same time)
5º All the relays and switchs has been bypassed, to discard problems at this.
6º Voltage at O/W (is the same than O/G) (11,35V not 12V or more due to the voltage fall for the wire resistance, OK, so the CDI is being fed)
7º Continuity between B/W and ground (OK, so the CDI is connected to ground)
8º Continuity in the fuse of the start relay (OK)
9º Measures 1,2,3,4,6 and 7 have been made on the CDI connector (execept the plug cap, obviously) to discard discontinuiy at the wires.

Remains to be checked voltage peak at pulse generator (more than 1,8V according manual) and voltage peak at primary winding coil (more than 100V according manual) but I dont have the special adaptor needed to measeure the peaks with the multimeter, but an electrical mechanic told me that if the caracteristic impedance of the high coils and the coil of the pulse generator are right, the problem probably is not there.

So, I think that the problem only could be a Bad CDI. Tomorrow a friend lend me a CDI to check if the problem is it. But I dont know if the CDI from GS500 2004 is compatible with GS500 2003 electric system (If something could tell me if are compatible would appreciate it). Additional I think that the probability that the CDI spoil me just when I change the engine is really low, so I think there is something that escapes me, but I dont know that, help please, I'm really desperate, thank you all in advance.




:dunno_white: :dunno_white: :dunno_white: :dunno_white:

PD: The f%$king captchas are very difficult!!!!!!!!!
PD2: What creates the electric arc that ignites fuel in the cylinder? Is not spark plug? sooo what???
PD3: Whennn the GS was introduced in the US??? I dont know, and google dont tell me!!

bvsilveira

Just a little advice in the questions, try sparkplug, all togheter, that was what worked for me, the year is 1989. These questions just apears until you get 5 posts.

Kiwingenuity

#2
Hi There,

I have had a look at my manual for a 2003 wiring diagram, but really need the frame number to find the exact wiring diagram for your model. in my manual the following CDIs have the same color code for models WITHOUT the throttle position sensor. (you should have 7 wires on your bike)

  • UK GS500E
  • UK GS500 EL, M, N, P, R, S and T models
  • US GS500 EL, M, N, P, R, S and T models
  • UK GS500 EV, EW, EX, EY, K1 (2001), K2 (2002) models
  • US GS500 EV, EW, EX, EY, K1 (2001), K2 (2002) models
  • UK GS500 K3 (2003)
  • US GS500 EK

If your friend has a 7 wire CDI with the same color code it (should) work ( I would really recommend find out SGP part no. for your bike and your friends). Suzuki do tend to use the same parts between generations unless they really need to change something.

From what you have tested it is possibly the CDI but may be as simple as the pick up (pulse generator coil),  I would check the pulse generator coils have been re-installed correctly and they have been plugged in - without the pulse coil connected you will get no ignition coil / spark.

The pulse generator coil should be blue / black for common, brown and green/white for each cylinder pulse. EDIT noticed your diagram shows 2 wires - does your bike have 2 or 3 wires from pickup?

Good luck - hope this helps

metatron

Quote from: bvsilveira on July 20, 2015, 06:16:23 PM
Just a little advice in the questions, try sparkplug, all togheter, that was what worked for me, the year is 1989. These questions just apears until you get 5 posts.
Try SIGNAL GENERATOR (Thanks GSJack :) )

chuskeyto

#4
Quote from: Kiwingenuity on July 20, 2015, 10:26:54 PM
Hi There,

I have had a look at my manual for a 2003 wiring diagram, but really need the frame number to find the exact wiring diagram for your model. in my manual the following CDIs have the same color code for models WITHOUT the throttle position sensor. (you should have 7 wires on your bike)

  • UK GS500E
  • UK GS500 EL, M, N, P, R, S and T models
  • US GS500 EL, M, N, P, R, S and T models
  • UK GS500 EV, EW, EX, EY, K1 (2001), K2 (2002) models
  • US GS500 EV, EW, EX, EY, K1 (2001), K2 (2002) models
  • UK GS500 K3 (2003)
  • US GS500 EK

If your friend has a 7 wire CDI with the same color code it (should) work ( I would really recommend find out SGP part no. for your bike and your friends). Suzuki do tend to use the same parts between generations unless they really need to change something.

From what you have tested it is possibly the CDI but may be as simple as the pick up (pulse generator coil),  I would check the pulse generator coils have been re-installed correctly and they have been plugged in - without the pulse coil connected you will get no ignition coil / spark.

The pulse generator coil should be blue / black for common, brown and green/white for each cylinder pulse. EDIT noticed your diagram shows 2 wires - does your bike have 2 or 3 wires from pickup?

Good luck - hope this helps

I tried my cdi in a GS 500, 2004, works perfectly (despite of my CDI is connected with 7 of 14 pins in my bike, and in his bike my CDI is connected with 13 of 14 pins). Old picks up had 2 coils, but the news have 1 coil. It doesn't matter if the pick up have 2 or 3 wire (1 or 2 coils) because the connector which links the CDI with the picks up have only 2 wires, so if you connect a pick up with 2 coils (3 wires) automatically the third pin stays in the air, and the CDI uses only the signal that comes from 1 coil, staying the other coil disabled. Even so, I tried with 2 diferents pick up, one of them with 1 coil and the other with 2 coil and not work.

I put the electric diagram of my bike at the end of the post (page 399 of the service manual) so you need to find nothing. Also I put a electric diagram of the entire ignition system.

I have tested the contininuity between the cdi and the pick up and its correct. So now I have tested:

1º Resistance measurement pulse generator (376 ohms according manual, OK)
2º Resistance measurement between pulse generator (Br) and ground (infinite ohms, according manual, OK)
3º Measurement of resistance in primary winding coil high (5,4ohms and 5,3ohms according manual, OK)
4º Measurement of resistance between input terminals and plug cap, (secondary winding coil high) (29,5kohms and 30,1kohms in the manual lays between 18 and 30 kohms but I think that this is not the problem, because the measurements are nearly to the limit, and its difficult that the 2 coils fail at the same time)
5º All the relays and switchs has been bypassed, to discard problems at this.
6º Voltage at O/W (is the same than O/G) (I have connected a wire from the positive of the battery to the CDI feeding, to obtain the same voltage than in the terminals of the battery and discard failures in the feeding of the CDI)
7º Continuity between B/W and ground (OK, so the CDI is connected to ground)
8º Continuity in the fuse of the start relay (OK)
9º I put my CDI in other bike, and it works perfectly.
10º Measures 1,2,3,4,6 and 7 have been made on the CDI connector (execept the plug cap, obviously) to discard discontinuiy at the wires.
11º I tested with another 2 high coils.
12º I tested with another pick up.

Now Im going to explain the 7 pins that are connected to the CDI, and with this the entire ignition system of my bike (that is very easy) will be explained.

PIN 1 Terminal 1 of the two high coils and feeding (O/W where the feed enters to the CDI)
PIN 2 Terminal 2 of the coil number 1.
PIN 3 Terminal 2 of the coil number 2.
PIN 4 Terminal 1 of the coil of the signal generator. (pick up)
PIN 5 Terminal 2 of the coil of the signal generator. (pick up)
PIN 6 Ground.
PIN 7 Tachometer marker.

Points 6º, 9º, 11º and 12º has been updated.

Nothing more to check. Next step workshop :(

Thanks for all!

sledge

Static tests are all very well and a good starting point, they may identify certain fault conditions such as open circuits and low resistance shorts but you have to consider that you are testing at probably 3v and hundredths of amps. These components operate at 12v or more and are subject to significantly higher currents. Some faults simply wont show up unless you subject them to the same parameters.

If you don't have access to the factory kit that tests dynamically at voltages/currents the components see when actually operating and replicates the same conditions they are subject to when actually in use, or you are not prepared to pay the people who do have the kit the prices they want to carry out the tests you sometimes have no option but to take a guess and replace the part you suspect.

I have got round problems like this in the past by explaining the situation to local breakers and asking if I can buy second-hand used parts on a sale or return basis and replacing key parts such as ignition modules, reg/rects, coils etc one by one until the problem is sorted. For instance.....you could buy a CDI, reg/rect, coils, pick ups etc and swap them over until the problem goes away and the faulty component reveals itself. You then take the unused parts back for a refund. "Diagnosis by
substitution" is quick and easy and a trick that dealers often resort to except they will use brand new parts and put them back in the box and on the shelf after use.

chuskeyto

Quote from: sledge on July 23, 2015, 12:06:48 PM
Static tests are all very well and a good starting point, they may identify certain fault conditions such as open circuits and low resistance shorts but you have to consider that you are testing at probably 3v and hundredths of amps. These components operate at 12v or more and are subject to significantly higher currents. Some faults simply wont show up unless you subject them to the same parameters.

If you don't have access to the factory kit that tests dynamically at voltages/currents the components see when actually operating and replicates the same conditions they are subject to when actually in use, or you are not prepared to pay the people who do have the kit the prices they want to carry out the tests you sometimes have no option but to take a guess and replace the part you suspect.

I have got round problems like this in the past by explaining the situation to local breakers and asking if I can buy second-hand used parts on a sale or return basis and replacing key parts such as ignition modules, reg/rects, coils etc one by one until the problem is sorted. For instance.....you could buy a CDI, reg/rect, coils, pick ups etc and swap them over until the problem goes away and the faulty component reveals itself. You then take the unused parts back for a refund. "Diagnosis by
substitution" is quick and easy and a trick that dealers often resort to except they will use brand new parts and put them back in the box and on the shelf after use.

I understand what you 're telling me and I think a good idea. However my ignition system consists of:

-sparkplug (I've tried with differents ones and nothing, even I put my finger in the sparkplug cap)
-CDI (I've tried it in other bike and works perfectly)
-Pick up (I've tried with different one and not works)
-High coils (I've tried with different one and not works)

Following your method just missing me try another CDI in my bike (but if my CDI works in other bike, is very strange that the fail will be here). In addition what is getting me crazy is the fact that the ignition system started to fail after a engine change, with the same pieces that are involved in the ignition system and that never failed...

What do you do now? Where do you start?

Thanks!

sledge

The wiring loom and the various connectors.

chuskeyto

Quote from: sledge on July 23, 2015, 12:46:54 PM
The wiring loom and the various connectors.

Ok I'll try to find one and replace it.

thx

chuskeyto

Quote from: sledge on July 23, 2015, 12:46:54 PM
The wiring loom and the various connectors.

Well, I isolated de ignition system completly from my bike. I  put the feeding directly from batery to CDI and to high coils and separating this from the rest of the electric system. I  connected the generator signal directly to the CDI with new cables and I tested the continuity in all of them. I did the same between high coils and CDI. I didnt forget to connect the engine to ground to let the spark plugs made spark when I approach them to engine.
This assembly is like changing the wiring loom.

I checked all the components separately, I checked the wires and I changed it.

This is a crappy scheme of the entire ignition system, its very very easy, so I dont know WHAT THE f%$k is happening!!! What bothers me most is that I am an electrical engineer and this is frustrating for me...


Kiwingenuity

#10
Do you have an oscilliscope? are you able to see if the tachometer pulse is making it into the CDI?

Is it possible the tachometer coil magnet was lost during the rebuild? dropped the magnet / demagnetised it with excessive heat etc?

This is the most basic setup I can get away with for my 2k7 model



aside from a short or pinched conductor in your wiring loom It is very difficult to understand why it will not operate, as long as the connection to the battery from the engine block is good you should definately see a spark.


chuskeyto

Quote from: Kiwingenuity on July 23, 2015, 11:06:21 PM
Do you have an oscilliscope? are you able to see if the tachometer pulse is making it into the CDI?

Is it possible the tachometer coil magnet was lost during the rebuild? dropped the magnet / demagnetised it with excessive heat etc?

This is the most basic setup I can get away with for my 2k7 model



aside from a short or pinched conductor in your wiring loom It is very difficult to understand why it will not operate, as long as the connection to the battery from the engine block is good you should definately see a spark.

There is a god idea. I thank in it when I could not get the adapter for the multimeter to measure the maximum peak of the generator signal coil and confirm that the generator signal is working right. But there's no posibility to get and osciloscopy to measure the pulse that outputs from the coil and check if this is correct.

About the magnet you left me completely baffled. Are you sure that in the rotor should be a magnet? Never I heard about it... There is no magnet in the rotor... I think that in this place there is no magnet. How is this magnet? Its strange that this magnet are bad in the two rotors that I have.

Your ignition system its equal to mine, but my ignition system with only one coil in the generator signal instead two (2 wires to the CDI instead 3)

thanks!

Kiwingenuity

I have not had the rotor out on my GS500 but assume it uses a hall effect sensor to provide the timing pulses to the CDI - The magent is usually set into the shaft and not easily removed - most likely not the problem if you have tried several rotors.

Is this what your signal generator looks like?



I also rummaged around and found someone who has had a similar problem:
http://www.gs500e.co.uk/forums/showthread.php?t=5272

They indicated that there should be a resistance of 250 to 420 ohms if you measure resistance between brown and blue wires of the signal generator. I know you have tried 2 pick up coils, but hopefully if you know one pick coil is good it is less to worry about.

Are you able to post a photo or two of your bike / wiring / test setup? are you using the bike wiring harness or have you set up temporary wiring? Are the coils mounted to the frame?

I hope we can help with this problem - it seems a very odd one.


Umar

Hi,

I have 2003 GS500e.. with VTTBK11110100 series VIN. (made in spain). I am having hard time fixing the wiring as I bought it from auction and igniter already missing. I was wondering if 2002 or 2004 model igniter would work. Both looks different. The 2004 has 12-14 wires. Can we install 2004 igniter on this. This bike has single pick up coil.

Any thoughts?

chuskeyto

#14
Quote from: Kiwingenuity on July 26, 2015, 12:54:32 AM
I have not had the rotor out on my GS500 but assume it uses a hall effect sensor to provide the timing pulses to the CDI - The magent is usually set into the shaft and not easily removed - most likely not the problem if you have tried several rotors.

Is this what your signal generator looks like?



I also rummaged around and found someone who has had a similar problem:
http://www.gs500e.co.uk/forums/showthread.php?t=5272

They indicated that there should be a resistance of 250 to 420 ohms if you measure resistance between brown and blue wires of the signal generator. I know you have tried 2 pick up coils, but hopefully if you know one pick coil is good it is less to worry about.

Are you able to post a photo or two of your bike / wiring / test setup? are you using the bike wiring harness or have you set up temporary wiring? Are the coils mounted to the frame?

I hope we can help with this problem - it seems a very odd one.

Thanks for your help. But I finished my holidays and I dont have time and desire for fix the problem. I decided to carry it to the workshop and dont brake my eggs more. I will comment you what the f%$k was wrong with the bike when it will be fixed.

Quote from: Umar on August 02, 2015, 01:39:17 AM
Hi,

I have 2003 GS500e.. with VTTBK11110100 series VIN. (made in spain). I am having hard time fixing the wiring as I bought it from auction and igniter already missing. I was wondering if 2002 or 2004 model igniter would work. Both looks different. The 2004 has 12-14 wires. Can we install 2004 igniter on this. This bike has single pick up coil.

Any thoughts?

http://forum.gs500.pl/ftp/Studi/Suzuki_GS_500_E_F_1989-2009_Service_Manual.pdf

I attached to you a link of the service manual, which contains all the wiring diagrams of all gs500 models. Maybe helps you the fact that CDI from 2002 and older will work in your bike, despite of the wiring diagram is different, the CDI are similar, but in differents models CDI adjust the ignition moment from diferent signals like the throttle sensor or similar, but it doesent matter. All of CDIs are compatible, they have the same pins number, but not all of these pins are connected in each model.
http://forum.gs500.pl/ftp/Studi/Suzuki_GS_500_E_F_1989-2009_Service_Manual.pdf

Muhammad Zubair Butt

Hi all,
I am zubair from pakistan, I had a gs500 2004 sapnish model, i want to know is gs500 2004bis single pulser or double pulser.

Cheers and regards.

The Buddha

US was a single - pulser means 1 crank trigger coil right ?
Open that little round cover on the right side and if you see 1 coil then its 1, if 2, its 2.
Cool.
Buddha.
-----------------------------------------------------------------
I run a business based on other people's junk.
-----------------------------------------------------------------

mr72

sounds def like it has to be the igniter. IMHO.

SMF spam blocked by CleanTalk